TL;DR
- An HPD does not earn LEED points by itself. In LEED v5 MR Credit Building Product Selection and Procurement (BPSP, MRc4), an HPD gives a product a Level 1 (1x) or Level 2 (2x) value in the Human Health criteria area.
- That value feeds the product’s multi-attribute score (MAS), which is summed across five criteria areas and capped at 5 per product.
- Points are awarded per product category, not per product. In BD+C, each category whose MAS-adjusted value exceeds 100% earns 1 point, up to 5 points.
- HPD Level 1 = published HPD, pre-checked for LEED, complete to 1,000 ppm, in the HPD Repository.
- HPD Level 2 = third-party verified HPD, inventoried to 100 ppm, with verification that the end-use product contains no GreenScreen LT-1 hazards or no GHS Category 1 hazards.
- An HPD cannot reach Level 3 in Human Health. Today only Cradle to Cradle Gold/Platinum (or a C2C Material Health Certificate at Gold or above) does.
- For spec writers: when a rep says “our product has an HPD,” ask which level and is it third-party verified?
First, a correction on timing: is LEED v5 mandatory?
Not yet. Earlier timelines had LEED v4/v4.1 commercial registration closing on June 30, 2026. On May 27, 2026, USGBC extended that by one year: LEED v4/v4.1 BD+C, ID+C and O+M now close to new registrations on June 30, 2027, and the certification sunset moved to June 30, 2033.
So as of November 2026, new commercial projects can still choose v4/v4.1 or v5. USGBC recommends v5 for new projects, and some jurisdictions already require it (for example, Boston Article 22 projects filing after April 29, 2026). v5 becomes the only option for new BD+C/ID+C/O+M registrations after June 30, 2027.
The practical point stands either way: any project registering under v5 is using the scoring below, and that share grows every month.
What is the LEED v5 Building Product Selection and Procurement credit?
BPSP (MRc4 in BD+C New Construction and Core and Shell, 1–5 points) replaces the v4.1 product credits (EPDs, Material Ingredients, Sourcing of Raw Materials) and the circularity and social-equity pilot credits with one multi-attribute framework.
Products are evaluated against five criteria areas:
- Human health
- Climate health
- Ecosystem health
- Social health and equity
- Circular economy
Each area has three achievement levels, which work as multipliers:
| Level | Meaning (USGBC) | Multiplier |
| Level 1 | First step toward sustainability in the criteria area | 1x |
| Level 2 | Leadership position in the marketplace | 2x |
| Level 3 | Elite / forefront of sustainability | 3x |
In BD+C, the credit covers nine nonstructural product categories: paints and coatings, adhesives and sealants, flooring, walls, ceilings, insulation, furniture, composite wood, and plumbing fixtures.Structural/enclosure/hardscape and MEP products follow the same scoring in separate Project Priority credits (MRpc181 and MRpc185).
How does the scoring math work?
Step 1: Score each product per criteria area. Each eligible product document is mapped to a value (1, 2 or 3) in one or more criteria areas, using USGBC’s Table 1 of eligible product documentation.
Step 2: Take only the highest value in each area. Values do not stack within a criteria area. A product with a Level 2 HPD and a Level 1 Declare label still scores 2 in Human Health, not 3.
Step 3: Add across areas to get the MAS (max 5). Values do add across areas. A Level 2 HPD (Human Health = 2) plus a product-specific Type III EPD (Climate Health = 1) gives MAS = 3.
Step 4: Weight each product’s value.
Product value (cost, area, volume or unit) × MAS = Adjusted product value for LEED
Step 5: Roll up by category.
Category adjusted value = 100 × (sum of adjusted product values) ÷ (total value of all products in the category)
Step 6: Award points. In BD+C, each category whose adjusted value exceeds 100% earns 1 point, to a maximum of 5 points (five categories). Compliance is calculated in USGBC’s calculator in Arc.
ID+C is different. In LEED v5 ID+C (Commercial Interiors), a category that exceeds 100% earns 1 point and one that exceeds 200% earns 2 points, up to 10 points total.
Where does an HPD fit? Level 1 vs. Level 2
In the USGBC scoring table, HPDs appear only in the Human Health column. Nothing else on an HPD earns climate, ecosystem, social or circularity value in BPSP.
| HPD Level 1 | HPD Level 2 | |
| USGBC table row | “HPD: Pre-Checked for LEED, min 1000ppm” | “HPD: Third-Party Verified, 100ppm, Avoidance of Chemicals of High Concern” |
| Human Health value | 1 (1x) | 2 (2x) |
| Inventory threshold | 1,000 ppm (0.1%) | 100 ppm (0.01%) |
| Hazard requirement | Full disclosure of known hazards per the HPD Open Standard | Verification of either no GreenScreen LT-1 hazards or no GHS Category 1 hazards in the end-use product |
| Third-party verification | Not required | Required, including verification of the content inventory |
| LEED pre-check | Pre-checked for LEED | Pre-checked for LEED v4.1 Material Ingredients Option 2 |
| Publication | Published in the HPD Repository | Published, verified HPD |
| Must be visible on the document | Product name(s), type and description; unique ID; inventory to ≥1,000 ppm; validity period | Same, plus inventory to ≥100 ppm and an indication of third-party verification of the content inventory |
Level 3? Not available to an HPD. In the current USGBC resource, Human Health Level 3 is met only by Cradle to Cradle Certified Gold or above (v3.1/v4/v4.1) or a C2C Material Health Certificate at Gold or above.
The most common misstatement: “pre-checked” means “verified”
It doesn’t. HPDC’s own manufacturer guide describes the LEED Pre-Check Indicator as an optional, manufacturer-selected cross-check. It confirms that required fields are filled in and that the basic LEED requirements appear to be met (right threshold, contents characterized, screened and identified). It does not assess data quality and does not verify that the information is accurate.
That is the Level 1 / Level 2 line:
- Pre-checked HPD → Level 1 (1x). Software-level completeness check.
- Third-party verified HPD, 100 ppm, no LT-1 / no GHS Cat 1 hazards → Level 2 (2x). An approved independent verifier has reviewed the content inventory.
Worked example: one flooring category (BD+C)
Total flooring spend on the project: $100,000.
| Product | Cost | Documentation | Human Health | Climate Health | MAS | Adjusted value |
| A | $40,000 | Third-party verified HPD (Level 2) | 2 | – | 2 | $80,000 |
| B | $30,000 | Pre-checked HPD (Level 1) + product-specific Type III EPD | 1 | 1 | 2 | $60,000 |
| C | $30,000 | None | – | – | 0 | $0 |
| Total | $100,000 | $140,000 |
Category adjusted value = 100 × 140,000 ÷ 100,000 = 140% → exceeds 100% → 1 point for flooring.
What the example shows:
- The HPD level matters a lot. If Product A’s HPD were only pre-checked (1x), the category would drop to 100%, which does not exceed 100%, and the point could be lost. (Confirm edge cases in the Arc calculator.)
- Stacking across criteria areas is the main lever. Product B reaches 2x without a verified HPD by pairing a Level 1 HPD with an EPD.
- Undocumented products drag the category down, because they count in the denominator at zero.
- One great product doesn’t earn a point alone. Points come from whole categories.
What should spec writers ask a manufacturer rep?
When you hear “our product has an HPD,” ask:
- Is it third-party verified? If yes, by which HPDC-approved verifier?
- What is the inventory threshold: 100 ppm or 1,000 ppm?
- Does the verification confirm no GreenScreen LT-1 or no GHS Category 1 hazards in the end-use product? (Needed for Level 2.)
- Is it published in the HPD Repository, and when does it expire? The validity period must be on the document.
- Does the HPD cover the exact product, type and description you’re specifying?
- What else do you have? A product-specific Type III EPD, FSC/PEFC/SFI labels, recycled content, an approved take-back program or Cradle to Cradle certification adds value in other criteria areas and lifts the MAS.
What should manufacturers take from this?
- Verify if you can. A verified 100 ppm HPD with no LT-1/GHS Cat 1 hazards doubles the Human Health value versus a pre-checked HPD.
- Pair the HPD with an EPD. A product-specific Type III EPD adds a Climate Health value of 1 (2 or 3 for an optimized EPD with 20%+ or 40%+ GWP reductions).
- Put the required fields on the document: product names, unique ID, threshold, validity period and, for Level 2, a verification statement.
- Track the addenda. USGBC says the scoring table is under continuous maintenance and will change through the LEED v5 addenda process. HPDC also offers a LEED v5 BPSP Multi-Attribute Scoring Tool for manufacturers.
FAQ
Does an HPD earn a LEED v5 point? No. It gives a product a Human Health value of 1 or 2. Points come only when a whole product category’s MAS-weighted value exceeds 100% (BD+C).
What is the maximum multi-attribute score for a product? 5, summed across the five criteria areas, using only the highest value in each area.
What is the difference between an HPD Level 1 and Level 2 in LEED v5? Level 1 is a published, pre-checked HPD complete to 1,000 ppm (1x). Level 2 is a third-party verified HPD to 100 ppm with verified absence of GreenScreen LT-1 or GHS Category 1 hazards (2x).
Can an HPD reach Human Health Level 3? No. Currently only Cradle to Cradle Certified Gold+ or a C2C Material Health Certificate Gold+ qualifies.
Do an HPD and a Declare label add together? No. Both sit in Human Health, so only the higher value counts.
Do an HPD and an EPD add together? Yes. They are in different criteria areas (Human Health and Climate Health), so their values add toward the MAS.
Is LEED v5 mandatory for new projects? Not yet. USGBC extended LEED v4/v4.1 commercial registration to June 30, 2027. After that date, new BD+C, ID+C and O+M registrations must use v5.
How many points is the BPSP credit worth? 1–5 points in LEED v5 BD+C (New Construction, Core and Shell); up to 10 in ID+C.
Sources
- USGBC, LEED v5 Reference Guide for Building Design and Construction, July 2026 edition, MRc4 Building Product Selection and Procurement.
- USGBC, Criteria Areas & Achievement Levels in LEED v5: Additional Guidance for the MR Credit Building Product Selection & Procurement, v1.3 (Feb 24, 2026), Table 1 and Human Health criteria.
- Health Product Declaration Collaborative, Manufacturer Guide to the HPD Open Standard Version 3.0, LEED Pre-Check Indicator.
- CaGBC: LEED v4/4.1 Registration Extension and Updates to Sunset Dates (May 27, 2026)
- LEEDuser: ID+C v5 MRc4 Building Product Selection and Procurement
- HPDC: LEEDv5 BPSP Multi-Attribute Scoring Tool
Scoring reflects the USGBC resource v1.3 and the July 2026 BD+C reference guide. USGBC updates the scoring table through LEED v5 addenda; check the current version before relying on it for a submission.